ARCHIPELAGO
Lighting Group
Catalog Number ✎ click to edit
LPAR38C90030K1
cityRCH · PRO TRAFFIC LAMP · LPAR-I
LPAR · Traffic PAR38
LED PAR38 Traffic Lamp · 25° Clear Optics · E26 Medium Screw Base
Spec-grade EVP confirm-beacon lamp. 7W / 10W / 14W at
390 / 900 / 1,500 lm.
Direct-replace screw-in for Opticom, STROBECOM, and legacy E26 PAR38 sockets.
3-year / 25,000-hour limited warranty.
Stock Status
QuickShip · 3-5 day
All 3 SKUs are QuickShip.
120Vac · Triac dimmable · ships individually.
One family. Three authoritative SKUs. LPAR is the EVP confirm-beacon lamp built specifically
for emergency-vehicle pre-emption signal heads (Opticom, STROBECOM, Federal Signal). Direct screw-in to existing
E26 PAR38 sockets — no controller rewire. CRI 93, FCC Part 15 compliant for RF-dense cabinets, dielectric grease
on the base for socket longevity. Black-Body 900lm variant MDOT-listed — the
only PAR38 LED on the Michigan QPL. 3-year / 25,000-hour limited warranty.
Ordering Code
5 segments · Family · Lamp · Optic · Lumens · CCT · Gen
| Segment |
Available Codes |
| LPAR | LED PAR-form-factor traffic / spec lamp family |
| 38 | Lamp envelope — PAR38 size (4.76″ Ø bulb) |
| C | Optic — C Clear · 25° narrow flood (sharp confirm-beacon throw) |
| 390 · 900 · 1500 | Lumens · Wattage · Body — 390 (7W · 4800K · White-Body · QS) · 900 (10W · 3000K · Black-Body · MDOT-listed · QS) · 1500 (14W · 3000K · White-Body · QS) |
| 30K · 48K | CCT — 30K 3000K Warm White (900 + 1500 lumens) · 48K 4800K Cool White (390 lumens only) |
| 1 | Generation — Gen-1 marker (every active LPAR ships as Gen-1) |
| Catalog Number |
Specifications |
| LPAR38C39048K1 | 7W · 390 lm · 4800K Cool White · White-Body · EVP confirm-beacon variant · UPC 815109025140 |
| LPAR38C90030K1 | 10W · 900 lm · 3000K Warm White · Black-Body · ★ MDOT Approved · -40°F to 165°F · UPC 815109028806 |
| LPAR38C150030K1 | 14W · 1,500 lm · 3000K Warm White · White-Body · legacy general-traffic flagship · UPC 815109028813 |
ARCHIPELAGO
Lighting Group
Catalog Number
LPAR38C90030K1
Detailed Specifications
LPAR · LED Traffic PAR38 · EVP Confirm Beacon
| Optical & Performance |
| Optic / Distribution | Clear 25° narrow flood · sharp confirm-beacon throw · single-axis beam |
| CCT (selected) | 3000K Warm White |
| CRI | CRI 93 · R9 65+ · R13 94+ (high reds + skin tones for EVP signal visibility) |
| Output · Lumens | 10W input · 900 lm output · 90 lm/W · Black-Body housing |
| Peak Intensity | ~3,420 cd (linear-scaled from 1,500lm reference 5,700 cd test) |
| Electrical |
| Input Voltage | 120Vac · 50/60Hz · single-input (NOT universal · 120V only) |
| Dimming | Triac dimmable · compatible with most line-voltage 120V Triac dimmers · non-flicker |
| Power Factor | PF > 0.90 at full load |
| RF / EMI | FCC Title 47 Part 15B compliant · tested for RF-dense traffic-cabinet environments (cellular modem, EVP detector, controller, Triac dimmer, surge protector co-located) |
| Construction & Socket |
| Base | E26 medium screw base · brass contacts with dielectric grease (factory-applied) for socket longevity in sealed cabinets |
| Housing | Cast aluminum body · heat-sink fin geometry · thermalRMOR cabinet-thermal design |
| Body Color (selected) | Black-Body (MDOT non-reflective housing for sealed-cabinet light containment) |
| Dimensions | 4.76″ (121 mm) Ø bulb × 5.23″ (133 mm) overall length |
| Net Weight | ~10.14 lb / case of 12 (~0.85 lb per lamp) |
| Compliance & Certifications |
| Listings | cULus Listed · FCC Title 47 Part 15B · RoHS · Wet Location · MDOT QPL-listed |
| Operating Temp | −40°F to +165°F (−40°C to +74°C) · sealed cabinet thermal envelope |
| Warranty | 7-year limited · 75,000-hour rated lifetime |
Dimensions & EVP Socket Compatibility
4.76″ Ø PAR38 · E26 medium screw base · 25° clear optic
PAR38 Bulb · Front + Side
EVP Confirm-Beacon Socket Compatibility
| Opticom OL11 / OL12 | Direct fit |
| TOMAR STROBECOM II | Direct fit |
| Federal Signal Opticom EVP | Direct fit |
| Generic E26 PAR38 · 120Vac | Direct fit |
| Socket Type | E26 medium screw |
| Mounting Hardware | None required |
| Beam Angle | 25° Narrow Flood · Clear Optic |
| Peak Lumen Output | 900 lm |
| Peak Efficacy | 90 lm/W |
| Peak Intensity | ~3,420 cd (linear-scaled from 1,500 lm test) |
| Photometric Reference | 1,500 lm SKU tested at 5,700 cd @ 0° · 390 lm and 900 lm SKUs scaled linearly |
| IES File | Not published — PAR38 lamps are tested in-fixture (signal-head + lamp), not as isolated lamps · isolated-lamp IES not available |
cULus Listed
FCC 47 / 15B
RoHS
Wet Location
MDOT Approved
3-yr / 25k-hr
thermalRMOR